The Helium Gas Charging Station is a high-pressure facility for decanting, hydrostatic testing, and refilling helium flight bottles used in helicopter emergency floatation systems. The system handles helium gas at 400 bar in bottles of 9 and 18 litre capacity, providing complete recovery of helium gas from returned bottles, hydrostatic testing at 1.5x working pressure, and refilling of tested bottles.

Key Specifications

Air Drive Pressure7 bar
Air Consumption40-50 SCFM
Flight Bottle SpecsWP 289 bar (18L) / WP 239 bar (9L)
Rejection Pressure After Decanting15-20 bar
Maximum Recovery Pressure>150 bar
Recharging PressureWP 289 bar (18L) / WP 239 bar (9L)
Request a Quote

Key Features

01

High-pressure safety interlocks against sudden pressure rise

02

All measuring instruments calibrated from certified labs

03

High-pressure containers shielded with robust metal cover

04

Proper helium vent routing for operator safety

05

Complete QA certificates (leak test, operational, relief valve, pilot switch)

06

Helium gas recovery and recycling capability

Chat with us